§ 170.315(c)(1)
Clinical quality measures (CQMs) — record and export
Get Email Updates
Certification Companion Guide
Test Procedure
Certification Companion Guide
v1.1
View Changelog
Issued Date:
03-11-2024
07-23-2025
This Certification Companion Guide (CCG) is an informative document designed to assist with health IT product certification. The CCG is not a substitute for the requirements outlined in regulation and related ONC final rules. It extracts key portions of ONC final rules’ preambles and includes subsequent clarifying interpretations. To access the full context of regulatory intent please consult the
Certification Regulations
page for links to all ONC final rules or consult other regulatory references as noted. The CCG is for public use and should not be sold or redistributed.
Quick Overview
Required Updates
None
Design and Performance
Additional Criterion Information
Base EHR Definition
Included
Real World Testing
Yes
Insights Condition
No
SVAP Versions
Yes
CLARIFICATIONS
REGULATORY
STANDARDS
DEPENDENCIES
RESOURCES
CHANGELOG
IN THIS SECTION
Certification Clarifications
Technical Explanations and Clarifications
Search and Filter
Search Here...
Filter By Paragraph
All
Paragraph (c)(1)(i)
Paragraph (c)(1)(ii)
Sort:
Clarifications:
Health IT needs to be able to record all data necessary to successfully calculate selected clinical quality measures (CQMs).
Health IT developers are permitted to test and certify to the newest versions of the HL7® CDA® R2 Implementation Guide: Quality Reporting Document Architecture - Category I (QRDA I) and Category III (QRDA III) IGs, regardless of the versions approved by the National Coordinator via the
Standards Version Advancement Process (SVAP)
The specific version, number, and type of CQMs presented for certification are determined at the developer’s discretion. ONC recommends developers consult any CMS or other programs’ requirements around the specific version, number, or type of CQMs required for providers in determining the CQMs presented for certification.
Certain CMS programs require or provide the option for electronic CQM (eCQM) reporting. These programs include the Promoting Interoperability Programs, the Physician Quality Reporting System, the Hospital Inpatient Quality Reporting Program, the Comprehensive Primary Care (CPC) initiative, CPC Plus, and the Value-Based Payment Modifier Program. Each year, CMS issues annual updates to eCQMs (herein referred to as the “CMS annual measure update(s)”) which are published on the
Electronic Clinical Quality Improvement (eCQI) Resource Center
. The CMS annual measure updates rely upon a specific version of the Quality Reporting Document Architecture (QRDA) Category I standard. Each year’s QRDA Category I standard is referenced in the corresponding
CMS QRDA Implementation Guide
(IG) associated with that program year and CMS annual measure update. The CMS QRDA IG also contains additional programmatic form and manner requirements necessary for reporting to CMS programs, which make it necessary for the corresponding testing tools to keep pace with these measure updates and CMS reporting requirements. Thus, health IT developers are permitted to be tested and certified to the applicable CMS annual measure update and use the corresponding version of QRDA Category I standard referenced in the CMS QRDA IG. ONC will evaluate the need for future rulemaking to align the version of QRDA Category I standard required for this certification criterion with the version of QRDA Category I standard in the CMS annual measure update.
After technology is certified to specific CQMs for this § 170.315(c)(1) criterion, technology is not required to recertify to the annual measure specification updates CMS issues to maintain certification unless that product is relabeled. Said another way, other programs, such as the Promoting Interoperability Programs, may require developers to upgrade their technology to the newest CQM specifications, but the technology is not required to be retested or recertified for eCQMs already certified unless explicitly specified in other program requirements. It is expected that all systems will test all measure and standards updates as a best practice. The testing tools are available for each CMS annual measure update and when there are late standards errata or CMS requirement changes to facilitate additional testing for products using eCQMs.
For the purposes of automated testing to meet certification requirements, only errors (but not warnings) generated during testing would constitute a failure to meet certification requirements.
Technical outcome – The health IT must be able to record all data necessary to calculate CQMs presented for certification.
Clarifications:
Providers may employ many methods to capture the information required by CQMs. Information transferred from other systems can meet the requirement for “capture.” [see also
77 FR 54230
] ONC recommends developers include functionality that allows users to view any information transferred from other systems.
ONC-Authorized Testing Labs (ONC-ATLs) are permitted to provide flexibility regarding data elements for manual entry where the measure allows multiple ways to express the same data criteria or alternate data criteria where appropriate.
Data required for CQM exclusion or exceptions must be codified entries and may include specific terms defined by each CQM selected. Free text is permitted to be captured in addition to the minimum requirement to capture data as a codified entry.
Specific reasons why an action was performed or not performed to determine whether the patient meets an exclusion or exception should be recorded as part of the generated QRDA Category I file.
Technical outcome – A user can export a data file formatted in accordance with HL7® QRDA Category I Release 3 or the corresponding version of the QRDA standard for the CMS annual measure update being certified for one or multiple patients that includes all of the data captured in (c)(1)(i) of this criterion.
Clarifications:
A user of this health IT must be able to create these reports at any time selected without additional assistance from health IT developers. This will allow a provider or health system to view and verify their CQM results for quality improvement on a near real-time basis. It also gives providers the ability to export their results to multiple programs, such as those run by CMS, states, and private payers, and/or reporting solutions, such as registries or other types of data intermediaries. While a user of this health IT must be able to create these reports at any time selected without additional assistance from health IT developers, health IT developers can claim technology downtime for software upgrades (to accommodate upgrades for the latest QRDA specification, for example). Health IT developers experiencing technology downtime for software upgrades should communicate their reason for technology downtime and when their technology will again be operational. [see also
77 FR 54230
and
80 FR 62650
Testing and Certification. Successful testing and certification does not require the evaluation of the time required to process a CQM data file. To illustrate, a delay between when a user initiates an export and receives the resulting data file would not, by itself, preclude successful testing of the technology or the issuance of a certification on the basis of those successful test results.
Surveillance. While the CQM export capability does not require that data be received instantaneously, a non-conformity would exist if surveillance revealed that processing or other delays were likely to substantially interfere with the ability of a provider or health system to view and verify their CQM results for quality improvement on a near real-time basis. [
80 FR 62650
] Similarly, a non-conformity would exist if delays were causing or contributing to users being presented with data files that no longer contained current, accurate, or valid data. To avoid these implementation issues and ensure that capabilities support all required outcomes, health IT developers should seek to minimize processing times and other delays to the greatest extent possible. ONC notes also that any delays must be disclosed in accordance with § 170.523(k)(1).
Providers and health systems should determine the protocols around when and how providers export CQM data. As noted above, for testing, the health IT would need to demonstrate a user can export data formatted to QRDA Category I for one or more patients without needing additional developer support. [see also
80 FR 62650
STANDARDS REFERENCED
§ 170.205(h)(2)
Health Level 7 (HL7®) CDA® Release 2 Implementation Guide for: Quality Reporting Document Architecture – Category I (QRDA I); Release 1, DSTU Release 3 (US Realm), Volume 1
Regulation Text
§ 170.315(c)(1) Clinical quality measures—record and export—
(i) Record.
For each and every CQM for which the technology is presented for certification, the technology must be able to record all of the data that would be necessary to calculate each CQM. Data required for CQM exclusions or exceptions must be codified entries, which may include specific terms as defined by each CQM, or may include codified expressions of “patient reason,” “system reason,” or “medical reason.”
(ii) Export.
A user must be able to export a data file at any time the user chooses and without subsequent developer assistance to operate:
Formatted in accordance with the standard specified in § 170.205(h)(2);
Ranging from one to multiple patients; and
That includes all of the data captured for each and every CQM to which technology was certified under paragraph (c)(1)(i) of this section.
Standards & References
The following standards are referenced within the certification criteria for:
§ 170.315(c)(1) Clinical quality measures (CQMs) — record and export
View By
Standard
Paragraph
§ 170.205(h)(2)
Health Level 7 (HL7®) CDA® Release 2 Implementation Guide for: Quality Reporting Document Architecture – Category I (QRDA I); Release 1, DSTU Release 3 (US Realm), Volume 1
Referenced in the Following:
Paragraph (c)(1)(ii)
SVAP-approved Versions:
§ 170.205(h)(2) HL7® CDA® R2 Implementation Guide: Quality Reporting Document Architecture - Category I (QRDA I); Release 1, STU Release 5.3 with errata - US Realm, December 2022
Paragraph (c)(1)(ii)
Export
§ 170.205(h)(2)
Health Level 7 (HL7®) CDA® Release 2 Implementation Guide for: Quality Reporting Document Architecture – Category I (QRDA I); Release 1, DSTU Release 3 (US Realm), Volume 1
Certification Dependencies
§ 170.405
Real World Testing
Products certified to this criterion must complete requirements outlined for the Real World Testing Conditions and Maintenance of Certification.
Note: For calendar year (CY) 2025, a developer is not expected to submit an annual Real World Testing plan to its ONC-Authorized Certification Body (ONC-ACB) for the 2026 Real World Testing year. For CY 2026, ONC only expects a developer with a Health IT Module(s) certified to the (g)(7) through (10) certification criteria, as of August 31, 2024, to submit a CY 2025 Real World Testing results report to its ONC-ACB by March 2026.
Please read the full notice
outlining the details of the Real World Testing enforcement discretion.
Privacy and Security
This certification criterion was adopted at § 170.315(c)(1). As a result, an ONC Authorized Certification Body (ONC-ACB) must ensure that a product presented for certification to a § 170.315(c) criterion includes the privacy and security criteria (adopted in § 170.315(d)) within the overall scope of the certificate issued to the product.
The privacy and security criteria (adopted in § 170.315(d)) do not need to be explicitly tested with this specific paragraph (c) criterion unless it is the only criterion for which certification is requested.
As a general rule, a product presented for certification only needs to be tested once to each applicable privacy and security criterion (adopted in § 170.315(d)) so long as the health IT developer attests that such privacy and security capabilities apply to the full scope of capabilities included in the requested certification. However, exceptions exist for § 170.315(e)(1) “View, download, and transmit to 3rd party (VDT)” and (e)(2) “Secure messaging,” which are explicitly stated.
§ 170.315(d)(2)(i)(C) is not required if the scope of the Health IT Module does not have end-user device encryption features.
For more information on the approaches to meet these Privacy and Security requirements, please download the Privacy and Security CCG below:
Privacy and Security CCG
If choosing
Approach 1
Authentication, access control, and authorization (§ 170.315(d)(1))
Auditable events and tamper-resistance (§ 170.315(d)(2))
Audit reports (§ 170.315(d)(3))
Automatic access time-out (§ 170.315(d)(5))
Encrypt authentication credentials (§ 170.315(d)(12))
Multi-factor authentication (MFA) (§ 170.315(d)(13))
If choosing
Approach 2
For each applicable privacy and security certification criterion not certified for Approach 1, the health IT developer may certify using system documentation which is sufficiently detailed to enable integration such that the Health IT Module has implemented service interfaces the Health IT Module to access external services necessary to meet the requirements of the privacy and security certification criterion. Please see the
21st Century Cures Act: Interoperability, Information Blocking, and the ONC Health IT Certification Program
Final Rule at
85 FR 25710
for additional clarification.
Design and Performance
The following design and performance certification criteria (adopted in § 170.315(g)) must also be certified in order for the product to be certified.
Quality management system (§ 170.315(g)(4))
: When a single quality management system (QMS) is used, the QMS only needs to be identified once. Otherwise, the QMS’ need to be identified for every capability to which it was applied.
Accessibility-centered design (§ 170.315(g)(5))
: When a single accessibility-centered design standard is used, the standard only needs to be identified once. Otherwise, the accessibility-centered design standards need to be identified for every capability to which they were applied; or, alternatively, the developer must state that no accessibility-centered design was used.
Resources
The following resources can offer assistance or additional information:
§ 170.315(c)(1) Clinical quality measures (CQMs) — record and export
PDF DOCUMENT
Real World Testing Resource Guide
2025-10-01
PDF DOCUMENT
Real World Testing Fact Sheet
Certification Companion Guide Changelog
The following changelog applies to:
§ 170.315(c)(1)Clinical quality measures (CQMs) — record and export
Changelog functionality is not available.
Revision History
Version #
Description of Change
Version Date
1.0
Initial Publication
03-11-2024
1.1
Added update to Certification Dependencies section to reflect recent Real World Testing enforcement discretion notice.
07-23-2025
Test Procedure
v1.0
View Changelog
Issued Date:
03-11-2024
This Test Procedure illustrates the test steps required to certify a Health IT Module to this criterion. Please consult the most recent ONC Final Rule on the
Certification Regulations
page for a detailed description of the certification criterion with which these testing steps are associated. ASTP/ONC also encourages developers to consult the Certification Companion Guide in tandem with the test procedure as it provides clarifications that may be useful for product development and testing.
Quick Overview
Required Updates
None
Design and Performance
Additional Criterion Information
Base EHR Definition
Included
Real World Testing
Yes
Insights Condition
No
SVAP Versions
Yes
TESTING STEPS
TOOLS AND DATA
TESTING COMPONENTS
CHANGELOG
IN THIS SECTION
View Regulation Text
Testing Steps
Note: The tests step order does not necessarily prescribe the order in which the tests should take place.
Search and Filter
Search Here...
Filter By Paragraph
Filter By Date
Sort:
Testing Steps
System Under Test
Setup
The Health IT Module provides the following information in order to enable the creation of the (c)(1)(i) “Cypress Gold Standard Test Data” which includes instructions to enable the recording of CQM data within patient record(s):
Name of the health IT developer;
Name of the product;
List of CQMs to be certified; and
List of certification criteria to be tested (such as (c)(1) only or (c)(1), (c)(2), (c)(3) and (c)(4))
Record Entry
Using the instructions provided by Cypress, a user demonstrates they can record the specified data needed for each of the certified CQMs, using codified entries for data required for all CQM data criteria, including but not limited to support for codified:
patient reason;
system reason; and
medical reason.
Note: Record entry is not limited to use of a user interface. If a user interface entry is not available, the record entry can be demonstrated with the creation of structured documents (e.g. QRDA, C-CDA, or custom format) and their import into the SUT. These structured documents must be created by the health IT developer at the time of certification and must contain the specified data.
If a health IT developer is only testing to and seeking certification to § 170.315(c)(1), and not other CQM criteria (i.e. § 170.315(c)(2)-(c)(4)), record batch entry is not required to be tested.
Record Batch Entry
Using the “Cypress Gold Standard Test Data” instructions provided by Cypress, a user demonstrates the recording of data needed for each of the certified CQMs, using codified entries for data required for all CQM data elements.
Test Lab Verification
Setup
The tester creates the “Cypress Gold Standard Test Data” based upon the Health IT Module provided information using Cypress to create a new (c)(1) test instance.
Record Entry
Through visual inspection, the tester verifies the test data that is denoted for record entry can be recorded in a patient record within the Health IT Module, using the health IT developer identified data entry functions.
Note: If a health IT developer is only testing to and seeking certification to § 170.315(c)(1), and not other CQM criteria (i.e. § 170.315(c)(2)-(c)(4)), record batch entry is not required to be tested.
Record Batch Entry
The tester verifies through visual inspection the test data recorded for each of the certified CQMs can be batch recorded in a patient record within the Health IT Module, using the health IT developer identified entry functions.
The tester verifies through visual inspection that all of the test data that will be used to calculate each CQM has been recorded in a patient record within the Health IT Module for each of the CQMs to be certified.
The tester verifies through visual inspection the data required for CQM data criteria within the Health IT Module are codified entries.
Testing Steps
System Under Test
The health IT developer submits documentation that demonstrates how a user can export a file at any time the user chooses and without subsequent developer assistance.
Based upon the patient records updated in paragraph (c)(1)(i), a user exports, at any time and without any developer assistance, a data file formatted in accordance with the standard specified at § 170.205(h)(2) HL7
CDA
Release 2, Implementation Guide for: Quality Reporting Document Architecture – Category I (QRDA I); Release 1, DSTU Release 3, Volume 1 for a single patient and for multiple patients for each eCQM presented for certification.
Approved
SVAP Version(s)
170.205(h)(2) HL7
CDA
R2 Implementation Guide for: Quality Reporting Document Architecture – Category I (QRDA I); Release 1, STU Release 5.3 with errata - US Realm, December 2022
Test Lab Verification
Via documentation submitted by the health IT developer, the tester verifies that a QRDA I data file(s) can be exported at any time (on-demand) and without any developer assistance for one or more CQMs associated with one or more patients for the eCQMs chosen by the provider and for the chosen reporting period.
Using Cypress, the tester:
uploads the data file submitted by the Health IT Module; and
reviews the QRDA validation report for errors.
The tester verifies that the data file is formatted according to the standard specified at § 170.205(h)(2) for a single patient and multiple patients correctly and without omission.
Testers are permitted to randomly select, at their discretion, which individual patient from the batch entry recording will be used to export a QRDA Category I, file in order to demonstrate compliance in this area. The tester instructs the health IT developer to export the selected patient and confirms that this patient was exported.
Cypress Certification API (Alternative)
A tester may use the Cypress Certification API to upload the data file submitted by the Health IT Module. The tester can verify the results in Cypress as normal, however, the tester should manually verify all relevant steps of the TLV for at least one CQM to ensure this functionality is present, including reviewing the QRDA validation report for errors and that the data file is formatted according to the standard specified. Testers are permitted to randomly select, at their discretion, which individual patient from the batch entry recording will be used to export a QRDA Category I, file in order to demonstrate this functionality is present. The tester instructs the health IT developer to export the selected patient and confirms that this patient was exported.
TEST TOOL DOCUMENTATION
Testing Tools
§ 170.315(c)(1) Clinical quality measures (CQMs) — record and export
Cypress
Rigorous & repeatable testing of Electronic Health Records
Cypress is the rigorous and repeatable testing tool of Electronic Health Records (EHR) and EHR modules in calculating eCQMs used by CMS’s Quality Reporting Programs. The Cypress tool is open source and freely available for use or adoption by the health IT community including EHR vendors and testing labs. Cypress serves as the official testing tool for the EHR Certification program supported by the Office of the National Coordinator for Health IT (ONC).
Test Data
Test data for implementation and validation.
(c)(1)
Cypress Gold Standard Test Data created using Cypress
Testing Components
§ 170.315(c)(1) Clinical quality measures (CQMs) — record and export
Documentation is an approved method to demonstrate conformance. This may include documents from the health IT developer or third-party that demonstrate/attest to the compliance with the criterion.
Visual Inspection
Visual inspection is an approved method to demonstrate conformance. Most commonly, this will be accomplished via a live demonstration of functionality that meets the criterion.
Testing Tools
Testing tools indicate that a test tool(s) exists and must be used to test a portion or all of a Health IT Module's conformance to the criterion.
SVAP
Indicates that the Standards Version Advancement Process (SVAP) is applicable to the criterion.
Test Data
The test data for this criterion is provided within the testing tools tab. Click the link below to be directed to the testing tools tab.
Review Test Data
Test Method Changelog
The following changelog applies to:
§ 170.315(c)(1)Clinical quality measures (CQMs) — record and export
Changelog functionality is not available.
Revision History
Version #
Description of Change
Version Date
1.0
Initial publication
03-11-2024
The following design and performance certification criteria (adopted in § 170.315(g)) must also be certified in order for the product to be certified.
Additional Criteria:
§ 170.315(g)(4)
Quality management system
Description:
When a single quality management system (QMS) is used, the QMS only needs to be identified once. Otherwise, when different QMS are used, each QMS needs to be separately identified for every capability to which it was applied.
§ 170.315(g)(5)
Accessibility-centered design
Description:
When a single accessibility-centered design standard is used, the standard only needs to be identified once. Otherwise, the accessibility-centered design standards need to be identified for every capability to which they were applied; or, alternatively, the developer must state that no accessibility-centered design was used.
Loading Privacy & Security content...
Standards Version Advancement Process (SVAP)
The Standards Version Advancement Process (SVAP) permits health IT developers to voluntarily update health IT products certified under the ONC Health IT Certification Program (Certification Program) to newer versions of adopted standards as part of the "Real World Testing" Condition and Maintenance of Certification requirement (§ 170.405) of the 21st Century Cures Act.
Learn More About SVAP
SVAP Approved Version:
DECEMBER 2022
§ 170.205(h)(2) HL7® CDA® R2 Implementation Guide: Quality Reporting Document Architecture - Category I (QRDA I); Release 1, STU Release 5.3 with errata - US Realm, December 2022
Related to standard reference: § 170.205(h)(2)